{"product_id":"abwasser-hebeanlage-boy-1-5-mit-wirbelradpumpe-400-v-1-5-kw","title":"Boy 1.5 wastewater lifting station with vortex pump (400 V\/ 1.5 KW)","description":"\u003cp\u003e Single-plant design:\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Polyethylene collection container\u003c\/li\u003e\n\n\u003cli\u003e Compact unit with a 55 l capacity and adjustable switching volume from 19 l to 45 l, depending on the inlet connections used.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e Free-flow impeller pump with high efficiency and significantly reduced running noise, three-phase or single-phase current\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Boy with 140 l capacity and 70 l switching volume\u003c\/li\u003e\n\n\u003cli\u003e Single unit with mounted vortex pump,\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e with three-phase motor\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Sealing by mechanical seal and shaft seal\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e intermediate oil chamber\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Pressure outlet optionally DN 80 or DN 100\u003c\/li\u003e\n\n\u003cli\u003e Inlet for HT pipe DN 100, rotatable and height-adjustable\u003c\/li\u003e\n\n\u003cli\u003e Additional DN 40 (1 1\/2”) connections for hand diaphragm pump\u003c\/li\u003e\n\n\u003cli\u003e Vent DN 65 (ø 75)\u003c\/li\u003e\n\n\u003cli\u003e pneumatic level control ZPS 1, potential-free output for\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e Collective fault message and acoustic alarm\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e 3.5m connection cable to the motor\u003c\/li\u003e\n\n \u003cli\u003eBoy plant with larger emergency storage volume\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp\u003e Areas of application for individual systems:\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Pumping of domestic wastewater from a basement apartment or a single-family house\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp\u003e Double system design:\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Polyethylene collection container\u003c\/li\u003e\n\n\u003cli\u003e Compactboy double with 150 l capacity and 80 l switching volume\u003c\/li\u003e\n\n\u003cli\u003e Boy double with 200 l capacity and 100 l switching volume\u003c\/li\u003e\n\n\u003cli\u003e Boy twin system with mounted swirl wheel pumps, with three-phase motor\u003c\/li\u003e\n\n\u003cli\u003e Kompaktboy twin system with mounted free-flow impeller pumps\u003c\/li\u003e\n\n\u003cli\u003e Sealing by mechanical seal and shaft seal\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e intermediate oil chamber\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Pressure outlet DN 100\u003c\/li\u003e\n\n\u003cli\u003e Inlet for DN 100 HT pipe, rotatable and height-adjustable, also available for Boy double models.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e DN 150 with flange connection (optional accessories required)\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Additional DN 40 (1 1\/2”) connections for hand diaphragm pump\u003c\/li\u003e\n\n\u003cli\u003e Venting: Compactboy DN 65 (ø 75), Boy DN 100 (ø 110)\u003c\/li\u003e\n\n\u003cli\u003e pneumatic level control ZPS 2.1, automatically changing operation,\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e Peak load function and fault switching, potential-free output for\u003c\/p\u003e\n\n\u003cp\u003e Collective fault message and acoustic alarm\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e 3.5 m connection cable to the motor\u003c\/li\u003e\n\n \u003cli\u003eBoy double unit with larger emergency storage volume\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp\u003e Areas of application for dual systems:\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Disposal of domestic wastewater from apartment buildings, commercial facilities, etc.\u003c\/li\u003e\n\n\u003cli\u003e Facilities where wastewater disposal must not be interrupted.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp\u003e Scope of delivery: Lifting station including control unit, flexible connections for DN 100 pressure line and vent, check valve and Y-pipe (only for double systems)\u003c\/p\u003e\n\n","brand":"zehnder","offers":[{"title":"Boy 1.5 D","offer_id":56791265378685,"sku":"93 092 66","price":3333.25,"currency_code":"CHF","in_stock":true},{"title":"Boy 3.0 D","offer_id":56791265411453,"sku":"93 092 67","price":3525.45,"currency_code":"CHF","in_stock":true},{"title":"Compactboy 1.1 W","offer_id":56791265444221,"sku":"93 740 53","price":2463.25,"currency_code":"CHF","in_stock":true},{"title":"Compactboy 1.1 D","offer_id":56791265476989,"sku":"93 740 54","price":2417.8,"currency_code":"CHF","in_stock":true},{"title":"Compactboy Double 1.1 D","offer_id":56791265509757,"sku":"93 924 64","price":5286.1,"currency_code":"CHF","in_stock":true},{"title":"Compactboy Double 1.5 D","offer_id":56791265542525,"sku":"93 924 65","price":5460.3,"currency_code":"CHF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0912\/2647\/2829\/files\/img_9309266_hauptbild--1500.jpg?v=1756334979","url":"https:\/\/www.emmenbaum.ch\/en\/products\/abwasser-hebeanlage-boy-1-5-mit-wirbelradpumpe-400-v-1-5-kw","provider":"EMMENBAUM SHOP","version":"1.0","type":"link"}