• For hygienic hot water preparation using the instantaneous water heater principle from buffer storage tanks
• Plug-and-play (Schuko plug), insulated compact unit with high-efficiency pump
• Thermally long plate heat exchanger for ideal heat transfer
• Automatic speed control of the pump without additional control via the built-in sensor in the buffer return line
• Simple cascading for higher throughput
• Scope of delivery includes shut-off valves in the buffer circuit
Technical data:
• Plate exchanger material: Stainless steel 1.4401
• Insulation material: EPP
• Maximum operating temperature: 90°C
• Maximum operating pressure on the drinking water side: 6 bar
• Operating voltage: 230V/AC
with flow temperature limitation
• Thermostatic valve in the flow line: 65°C
• Kiss 65 circulation pump: UPM GEO 25-85 PWM
• Circulating pump Kiss 100: UPMXXL 120/3 PWM
• Buffer connection size: DN 32 (1 1/4") male thread
• Water connection size: DN 32 (1 1/4") male thread
• Dimensions (H x W x D) with insulation: 760 x 480 x 260 mm
Design: Plate heat exchanger with Sealix surface protection
• For problematic drinking water
*Performance data: Buffer tank supply 65°C, cold water 10°C, hot water 45°C
| Power [kW] | 162* |
|---|---|
| Unit price | CHF/piece |
| Flow rate [l/min] | 65* |