- Display range: 60,000 (illuminated) with bar graph
- Basic accuracy: 0.03%
- Voltage AC: 10 µV 1000 V
- DC voltage: 10 µV 1000 V
- Current AC: 0.01 µA – 10 A
- DC current: 0.01 µA 10 A
- Resistance: 0.01 Ω 60 MΩ
- Continuity / Diode: Yes / Yes
- Frequency network level / logic level: 0.001 Hz 5 kHz / 0.001 Hz 1 MHz
- Capacitance: 0.01 nF 10 mF
- Duty cycle: 0.01% 99.99%
- Temperature: 200°C to + 1090°C
- 4 mA 20 mA DC current loop: 0% (4 mA) 100% (20 mA)
- Filter function: HFR filter (1000 kHz)
- Memory function: HOLD/AHOLD, MIN/MAX/AVG, PEAK/REL
- Socket control: µA/mA, input A
- Measurement method: TRUE RMS (AC, AC+DC)
- Backlit digital display with 60,000 digit resolution
- TRUE RMS true RMS measurement (AC and AC+DC) for measuring non-linear signals
- MIN/MAX/Average and fast PEAK recording (250 μs)
- Socket monitoring (optical/acoustic) in the μA/mA and A range with warning in case of incorrect operation (fuse protection)
- AutoV function for automatic AC/DC switching and measurement range selection
- Low-pass filter (HFR high-frequency rejection, 1000 Hz) for measurements on clocked motor drives
- Display HOLD and AutoHOLD when the measured value is stable
Application:
- The new TRUE RMS digital multimeter in an ergonomic, rubber-molded 2kg housing masters the most demanding measurement tasks in electrical work, industry, service, and HVAC technology.
Electrical trades:
- Low-impedance (LoZ) voltage measurement with low input impedance (>2 kΩ) for suppressing capacitively/inductively induced voltages
- Measurement of the CP control signal (duty cycle/amplitude) of EV charging stations (wallboxes) for electric vehicles
Industry:
- TRUE RMS voltage and frequency measurement on frequency converter drives and on loads with superimposed harmonics
- Measurement of the 4 mA 20 mA current loop signal in process engineering
Service:
- AutoV function with automatic switching (AC/DC) and measurement range selection for quick troubleshooting
- Optical and acoustic continuity testing with fast response time (< 100 µs) for detecting defective components, cable breaks and loose terminals
- HVAC Technology:
- µA measuring range for measuring flame sensors (ionization current) and measuring the sacrificial anode current (mA) of hot water storage tanks
- Measurement of temperature and exhaust gas temperature in heating, ventilation and air conditioning systems
Measurement function specific:
- TRUE RMS voltage measurement (1000 V)
- TRUE RMS current measurement (10 A, 20 A for 30 s.)
- Resistance measurement (60 MΩ)
- Capacitance measurement (10 mF)
- Frequency measurement (mains and logic levels)
- Duty cycle measurement (%)
- 4 mA 20 mA Current loop measurement (%)
- Temperature measurement (°C)
- Fast continuity test (< 100 μs) with visual and acoustic indication
- Diode testing
- Volt sensor function (non-contact and single-pole phase testing)
- Scope of delivery:
- Integrated rubber protective frame
- Protective case
- High-quality silicone test leads with gold-plated 2 mm and screw-on 4 mm test tip
- Wire temperature sensor
- Batteries (3 x 1.5 V Micro AAA)
| Brand | BENNING |
|---|---|
| Manufacturer part number | 044690 |
| Unit price | CHF/piece |
| EAN | 4014651446908 |
Fast delivery
Quality and responsibility
Competent advice
Secure payment