- Single-stage, fixed-setting exhaust gas temperature monitor in a protective housing
- Fully wired with 2 meters of temperature-resistant power cord
- High temperature resistance due to metal and ceramic materials for direct mounting on the flue pipe
- TÜV tested with test number, approved for use in thermal engineering systems
- Complete with mounting hardware and detailed operating and assembly instructions
- Intrinsically safe design, maintenance-free, energy-saving, as it requires no external auxiliary power
Technical data:
- Changeover contact, switching capacity 16(4) A 400V at cos = 1(0.6)
- Permissible ambient temperature: max. 180°C at the switch housing
- Medium temperature: 0...500°C
- Switching differential: approx. 15 K
- Stainless steel sensor: Length 120mm, immersion depth at least 105mm
- Time constant: < 45 seconds
- Installation position: any
- Storage temperature: 15°C...50°C
- Protection class according to DIN EN 60529: IP 40
- Switch design: Spring-loaded switch
Application:
- Bivalent operation with gas or oil heating, to lock it when the solid fuel boiler is in operation.
- Monitoring tasks to switch off the exhaust system in rooms with open or closed fireplaces, thus preventing the backflow of exhaust gases into the rooms when the fireplace is burning.
- ATW DIN EN 14597:201209
| Version | 100°C |
|---|---|