outdoor unit
- For heating and cooling operation
- Eligible for funding under BEG
- Operation with refrigerant R32
- Inverter power control, twin rotary compressor
- Night mode (Silent Mode)
- Flow temperature up to 55 °C
- Heat pump heating operation down to 20 °C
- Operating voltage: 230 V
Indoor unit:
- Coaxial copper tube heat exchangers for safe and efficient operation
- Integrated heating element: 3 kW
- High-efficiency circulation pump
- Weather-compensated control
- Fully pre-assembled, for floor installation
- Hot water storage tank 190 l, enamelled with impressed current anode
- Heating element integrated in the hot water storage tank for peak load coverage
- Safety features: Expansion vessel (8 l), pressure gauge, safety valve
|
Type
|
LWPK AI
|
5
|
6
|
8
|
10
|
|
Energy Efficiency Class for Low-Temperature Space Heating
|
A+++ to D
|
A+++
|
A+++
|
A+++
|
A+++
|
|
Energy Efficiency class for space heating, medium temperature
|
A+++ to D
|
A++
|
A++
|
A++
|
A++
|
|
Heating output /COP according to EN 14511
|
|
|
|
||
|
[kW/]
|
4.15 / 4.04
|
5.01 / 3.8
|
5.56 / 3.46
|
7.59 / 3.4
|
|
[kW/]
|
4.5 / 4.74
|
5.5 / 4.65
|
7.50 / 4.43
|
9.50 / 4.50
|
|
[kW/]
|
4.4 / 2.7
|
5 / 2.63
|
5.7 / 2.68
|
8.9 / 2.65
|
|
Dimensions of outdoor unit (W x H x D)
|
[mm] |
886 x 632 x 353
|
886 x 632 x 353
|
907 x 716 x 353
|
940 x 998 x 365
|
|
Dimensions of indoor unit (W x H x D)
|
[mm] |
648 x 1863 x 684
|
648 x 1863 x 684
|
648 x 1863 x 684
|
648 x 1863 x 684
|
|
Weight of outdoor unit
|
[kg]
|
39
|
39
|
42
|
62
|
|
Weight of indoor unit
|
[kg]
|
145 |
145
|
145
|
145
|
|
Ref. No.
|
524879
|
524880
|
524881
|
524882
|
| Brand | Austria Email |
|---|---|
| Manufacturer part number | 524879 |
| Unit price | CHF/piece |
| Ref. No. | 524879 |
| Type | LWPK AI 5 |
| EAN | 9004464248795 |