• Container: Stainless steel (1.4404)
• EV-TEDS 300 to EV-TEDS 500 with 75 mm PU rigid foam composite insulation and 5 mm foil jacket in RAL 9010 white, pre-assembled
• Maximum operating pressure: 10 bar
• Maximum operating temperature: 95°C
• Recommended safety pressure: 6 bar
Heat exchanger:
• Smooth tube heat exchanger
• Maximum operating pressure: 16 bar
• Maximum operating temperature: 130°C
Equipment:
• Height-adjustable feet
• Analog thermometer
• From EV-TEDS 300 to EV-TEDS 500 with additional DN 40 (1 1/2") socket for accommodating an electric heating element
• Revision flange from EV-TEDS 400 to EV-TEDS 500
Technical data:
Type EV-TEDS-2W: 300 400 500
Dispensing capacity [l/h] top/bottom** tKW = 10°C 605/970 720/1180 830/1400
tWW = 45°C
Performance indicator NL* [WT] above: tKW = 10°C 1.9 2 3
tSP = 60°C
tWW = 45°C
Performance indicator NL* [WT] below: 8 15 18
Standby heat consumption [W]: 49 55 58
* To achieve the specified NL number, the boiler output must be greater than the specified continuous output.
** 10°C cold water/80°C flow temperature/45°C tap temperature
| Contents [l] | 291 |
|---|---|
| Overall height [mm] | 1726 |
| Brand | evenes |
| lower WT [m²] | 1.5 |
| Tilting dimension [mm] | 1845 |
| Unit price | CHF/piece |
| ø Inspection flange [mm] | - |
| Diameter with insulation [mm] | 660 |
| upper WT [m²] | 1.1 |
| Type | EV-TEDS-2W 300 |
| Energy Efficiency Class | A |