• Material: Steel (S235JR) enamelled according to DIN 4753 (TÜV-tested)
• EV-WP-TWS 300 to EV-WP-TWS 500 with 75 mm PU rigid foam composite insulation and 5 mm foil jacket in RAL 9010 white, pre-assembled
• EV-WP-TWS 600 to EV-WP-TWS 1000 with 120 mm insulation in RAL 9010 white, pre-assembled
• 300 - 500 l single-wound heat exchanger
• 600 - 1000 l double-wound heat exchanger
• 600 l with two cleaning openings
• Operating pressure: max. 10 bar
• Temperature: max. 95°C
• Recommended safety pressure: 6 bar
Heat exchanger:
• Operating pressure: max. 16 bar
• Temperature: max. 130°C
Equipment:
• Magnesium anode for additional corrosion protection
• Height-adjustable feet
• Analog thermometer
• EV-WP-TWS 300 with additional DN 40 (1 1/2") socket for accommodating an electric heating element
• Revision flange from EV-TWS 400
* To achieve the specified NL number, the boiler output must be greater than the specified continuous output.
** 10°C cold water/80°C flow temperature/45°C tap temperature
Technical data:
| Type EV- WP-TWS-1W : | 300 | 400 | 500 | 600 | 800 | 1000 | |
| Dispensing capacity** [l/h]: | tKW = 10°C | 1170 | 1410 | 1690 | 2100 | 3140 | 4170 |
| tWW = 45°C | |||||||
| Performance indicator NL* [WT]: |
tKW = 10°C |
14 | 19 | 24 | 28 | 37 | 49 |
|
tSp = 60°C |
|||||||
|
tWW = 45°C |
|||||||
| Heat loss [W]: | 49 | 55 | 58 | 104 | 117 | 140 |
| Contents [l] | 291 |
|---|---|
| Overall height [mm] | 1726 |
| Brand | evenes |
| lower WT [m²] | 3.8 |
| Tilting dimension [mm] | 1845 |
| Unit price | CHF/piece |
| ø without insulation [mm] | - |
| ø Inspection flange [mm] | - |
| Diameter with insulation [mm] | 660 |
| Type | EV-WP-TWS-1W 300 |
| Energy Efficiency Class | A |